Annex B (informative) — Rail sections outside the recommended limits

These catalog sections have a lip outside the recommended lip limits in A.0: more than 3.1 mm into the case, or more than 1.5 mm across the panel. A front panel does not sit flat on the mounting face of these rails.

Section Lip
Schroff 34560 H-LD 11.25 mm past the mounting face
HEITEC 3684.562 2.5 mm printed projection across the panel
Verotec 959-262227 10.71 mm past the mounting face
Verotec 959-262230 3.23 mm past the mounting face

EIS · Rail sections outside the recommended limits Lip too long: more than 3.10 mm into the case, or more than 1.50 mm across the panel. 3684.562 prints a 2.5 mm projection across the panel. Lip too long nVent Schroff34560 H-LD yes HEITEC3684.562 yes Verotec959-262227 yes Verotec959-262230 yes

HEITEC 3684.562 is also shallower than 25.0 mm, front face to back face. H-LD and both Verotec sections are also deeper than 28.5 mm.