4.4 Requirements register (normative)
Generated from data/requirements.json by tools/requirements.py. Do not edit by hand.
Each row is one requirement: its identifier, the product types it applies to in a claim and the condition that brings it in, its text, how it is verified (Annex A gives the methods), and why it exists. Rows are grouped by the part they are written in. Every product owes the rows of Part 2, Core; a product owes the rows of an optional interface of Part 3 where it has it; Part 4 binds the installer. A row with a bracket applies only to a product that has what the bracket names, such as a PWR-BUS entry or a COAX-IN, which its claim file shows. The register and the data models are the specification; the clause pages and the PDF render them, and a mismatch in a rendering is an error in the rendering. Each row's provenance (quoted, inherited, measured, calculated, or EIS) and the roles and interfaces it binds are recorded in data/requirements.json. Roles, interfaces, and product types are defined in Conformance. Clause prose cites identifiers without the EIS- prefix. From the first tagged edition an identifier is never reused, and a requirement whose meaning changes gets a new one.
| Product type | Core | Optional interfaces |
|---|---|---|
| module | 52 shall, 1 may | 23 shall |
| enclosure | 30 shall | 23 shall |
| bus board | 20 shall, 3 may | 23 shall |
| power supply | 29 shall, 1 may | 11 shall |
| cable | 6 shall | 4 shall |
Chapter 9 binds the person assembling a system, not a product: 9 rows.
Part 2 Core
5.1 Rack dimensions
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-RACK-001 | module, enclosure | One HP shall be 5.08 mm. | inspection | Every width in a row is a multiple of the HP, so quoting the IEC value lets panels and rails from different makers line up hole for hole. |
| EIS-RACK-002 | module, enclosure | One rack unit shall be 44.45 mm. | inspection | The rack unit sets the 3U and 1U heights that panels, rails, and 19-inch rack frames share, so quoting IEC keeps them all on one grid. |
| EIS-RACK-003 | enclosure | A rack-mount frame shall meet IEC 60297-3-101:2004 and IEC 60297-3-100:2008 for the flange width, flange mounting-hole positions and slot, the 3U height H1, and the 84 HP row width. | inspection | Meeting the IEC flange, tab, height, and row figures lets a rack-mount frame bolt into any 19-inch rack and hold a full 84 HP row. |
5.2 Modules
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-PANEL-001 | module | A module shall be 1U or 3U high. | inspection | These are the only two panel heights EIS defines; a module of any other height fits no conforming row. |
| EIS-PANEL-002 | module | An N HP panel shall be no wider than N × 5.08 mm, where N is a positive whole number. | inspection | A panel at or under its nominal width lets neighbors sit side by side without binding, so N HP of panels always fits an N HP row. |
| EIS-PANEL-003 | module | A module shall publish its width in HP and how far it extends behind the panel's back face. | inspection | A buyer compares these two figures with a row's published width and clear depth to know the module fits before buying it. |
| EIS-PANEL-004 | module | A front panel shall be no more than 2.0 mm thick. | inspection | The mounting-screw length window is computed for panels up to 2.0 mm; a thicker panel leaves too few threads engaged in the insert. |
| EIS-PANEL-005 | module | A patch jack shall be a 3.5 mm mono (TS) socket. | inspection | One patch connector across all modules means any patch cable joins any output to any input, whoever made the modules. |
| EIS-PANEL-006 | module | A 3U front panel shall be 128.5 mm high. | inspection | 128.5 mm is three rack units (133.35 mm) less 4.85 mm, which fits the panel inside the IEC 3U height H1 of 132.55 mm. |
| EIS-PANEL-007 | module | A 1U front panel shall be 39.65 mm high. | inspection | 39.65 mm, one rack unit less 4.80 mm, is the Intellijel 1U panel height, so 1U modules fit the 1U rows already in use. |
| EIS-PANEL-008 | module | Mounting holes shall be 3.0 mm in from the top and bottom panel edges. | inspection | A fixed inset from each edge puts every panel's holes on the same line as the rail inserts, whatever the maker. |
| EIS-PANEL-009 | module, enclosure | The mounting-hole span, on the panel and between the inserts of a row's two rails, shall be 122.5 mm at 3U and 33.65 mm at 1U. | analysis | The span is the panel height less twice the 3.0 mm inset, and the rails must match it or the panel holes miss the inserts. |
| EIS-PANEL-010 | module | Mounting holes shall be drilled Ø3.2 mm, or slotted 3.2 mm wide and no longer than 5.5 mm along the rail, centered on the hole position. | inspection | A 3.2 mm hole clears the 3.0 mm M3 screw with room for small position errors between panel and insert; a short slot along the rail takes up rail position error without letting the panel drop. |
| EIS-PANEL-011 | module | Each mounting hole shall be a whole number of HP plus 2.54 mm from the panel's nominal left edge. | analysis | Offsetting holes by half an HP from the nominal edge puts every hole on an insert hole, whatever the panel width and wherever it sits. |
| EIS-PANEL-012 | module, enclosure | A board shall stay at least 9.25 mm clear of the top and bottom panel edges, and a rail shall cover no more than 9.25 mm of the panel face at each edge. | inspection | (128.5 mm − 110 mm) / 2 is 9.25 mm, so the usual 110 mm board fits between rails that cover no more of the panel. |
| EIS-PANEL-013 | module, enclosure | A dimension of clauses 5.1 to 5.3 shall hold within the tolerance the register states for its requirement; a dimension with no tolerance stated is a limit. | measurement: each dimension of clauses 5.2 and 5.3 against its tolerance or limit | A nominal figure without a tolerance cannot be checked or rejected; one policy makes every mechanical figure measurable the same way. |
| EIS-PANEL-014 | module | A front panel thinner than 1.6 mm shall ship with M3 mounting screws with a head at most 7.0 mm across, whose length fits the window of clause 5.3 for its own thickness on a rail of the section clause 5.3 recommends. | inspection | The screw length window (RAIL-009) keeps the tip off the cavity floor only through a panel 1.6 mm or thicker; through a thinner one an enclosure's screws can bottom out, so the panel brings its own. |
| EIS-PANEL-015 | module | A module shall publish whether its front panel is connected to its 0 V, and whether the panel is bonded to the rails. | inspection | A panel at 0 V that is also bonded to the rails is a second chassis tie, and a panel that touches its neighbors joins two modules' 0 V; the installer can only avoid the loop if each module says what its panel is. |
5.3 Rails, inserts, and mounting screws
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-RAIL-001 | enclosure | The holes in a rail insert shall be 5.08 mm apart. | analysis | Insert holes one HP apart line up with panel holes placed on the HP grid, so a panel screws down at any position in the row. |
| EIS-RAIL-002 | enclosure | A rail for an N HP row shall give at least N × 5.08 mm of mounting length. | analysis | N panels at their full nominal width need N × 5.08 mm of rail, so a shorter rail cannot hold the row's published width. |
| EIS-RAIL-003 | enclosure | An insert shall be threaded M3. | analysis | The insert thread has to take the M3 mounting screw that every module hole is drilled to clear. |
| EIS-RAIL-004 | enclosure | An insert shall be at least 1.5 mm thick, three thread pitches. | analysis | An insert three 0.5 mm pitches thick gives the screw the three full threads RAIL-008 needs to hold a panel without stripping. |
| EIS-RAIL-005 | enclosure | A mounting screw shall be M3. | inspection | M3 is the thread of nearly every Eurorack case on sale and of the screws modules ship with, so one screw fits any row. |
| EIS-RAIL-006 | enclosure | A mounting screw's thread pitch shall be 0.5 mm. | inspection | Quoting the ISO 261 coarse pitch means any off-the-shelf M3 screw threads into any conforming insert. |
| EIS-RAIL-007 | enclosure | A mounting screw's major diameter shall be 3.0 mm. | inspection | Quoting the ISO 261 diameter fixes the size that the 3.2 mm panel hole and the rail throat are made to clear. |
| EIS-RAIL-008 | enclosure | A mounting screw shall engage at least three full threads through a 2.0 mm panel. | inspection | Three engaged threads through the thickest allowed panel keep a screw from stripping out as cables are plugged and pulled. |
| EIS-RAIL-009 | enclosure | The mounting-screw length L shall satisfy 2.0 mm + seat + 1.5 mm ≤ L ≤ 1.6 mm + D, with seat and D measured behind the rail's mounting face. The throat in front of the insert shall clear 3.0 mm. | analysis | The lower bound gives three threads through a 2.0 mm panel, and the upper keeps the tip off the cavity floor through a 1.6 mm panel. |
| EIS-RAIL-010 | enclosure | The mounting-screw head shall be at most 7.0 mm across. | analysis | The narrowest catalog rail face reaches 3.7 mm past the hole center (the Vector T-strut, half its 7.391 mm height), so a head up to 7.0 mm across bears on panel and rail face on every catalog rail; an ISO 7045 pan head and the common 7 mm M3 washer fit. |
| EIS-RAIL-011 | enclosure | An enclosure shall publish the mounting-screw length, and shall supply those screws or name them. | inspection | The right screw length depends on the rail's seat and cavity depth, which only the enclosure maker knows. |
5.4 Enclosures
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-ENC-001 | enclosure | An enclosure shall publish, for each row, its width in HP and the depth it keeps clear behind the panel's back face. | inspection | A buyer compares these figures with a module's published width and depth to know it fits the row before buying. |
6.1 Power architecture
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-PWR-001 | module, power supply, bus board, enclosure | A product shall publish, for each power entry, the maximum current it takes on each rail at the entry's nominal voltage, stating 0 for a rail it does not draw. | inspection | An installer sums these figures against the ratings of the source and of each product with outlets (ASM-001), and a buyer sizes a DC adapter from them; a stated 0 shows a rail was not forgotten. |
| EIS-PWR-002 | module, power supply, bus board, enclosure | A power supply, a bus board, and any product with power outlets shall publish the maximum current it delivers on each rail, in total and at each outlet. | inspection | An installer checks a row's summed currents against the source total and each outlet before adding a module (ASM-001); an outlet can be rated below its rail, and an overloaded trace or connector overheats. |
| EIS-PWR-003 | module, power supply | A product whose power entries are alternatives, each able to power it alone, shall not require more than one of them to be connected at the same time. | inspection | The installer connects only one of a product's alternative sources (ASM-003), so the product has to run from any one of them alone; entries that feed different circuits, such as a DC entry for one board and the bus for another, are not alternatives. |
| EIS-PWR-004 | module | A module shall not source current into a rail of any of its power entries. | inspection | A module that drives a rail fights its source's regulator and can back-power other products when the source is off. |
| EIS-PWR-005 | module, power supply, bus board, enclosure | Where a product takes or gives a rail or 0 V on row wiring, the discrete conductors between a power supply, a bus board, a DC entry, and PWR-DC12 outlets, each terminal shall be an M4 screw, stud, or threaded standoff that clamps a ring terminal under a lock washer, rated for at least the current it carries, and the product shall publish the conductor sizes its terminals accept. | inspection | One terminal on every supply, bus board, and DC entry means one ring terminal and one crimp tool for any pair of makers; a bolted ring does not work loose as a push-on tab can, and M4 is the ring the trade stocks from 22 to 10 AWG. |
| EIS-PWR-006 | module, power supply, bus board, enclosure | A row wiring conductor shall be insulated stranded copper rated 105 °C or more, with a crimped ring terminal at each end, of at least 18 AWG (16 AWG above 3 A, 14 AWG above 5 A, 12 AWG above 8 A, 10 AWG above 15 A), and shall carry no more than 25 A; a 0 V conductor carries the larger of the +12 V and +5 V currents together and the −12 V current. A joint shall not rely on solder alone. A 0 V link may instead be a tinned copper braid with crimped or pressed ring ends, or a copper bar, of no more resistance. | inspection | The gauges keep a conductor's heating small in a closed case, the temperature rating suits one, and a crimp holds where a soldered strand fractures; above 25 A a second pair shares the current. |
| EIS-PWR-007 | module, power supply, bus board, enclosure | Each row wiring conductor shall measure no more than 5 mΩ from ring terminal to ring terminal, and the 0 V conductor between a power supply and a bus board, or between linked bus boards, no more than any rail conductor beside it. | measurement: four-wire resistance of each conductor at 20 to 25 °C, ring terminal to ring terminal; or its gauge and length within the row wiring table of 6.1 | Every module in a row returns its current through the row wiring's 0 V, so its resistance couples each module's current into every other module's reference; Hinton Instruments sets 5 mΩ for supply cables for that reason. |
| EIS-PWR-008 | module, power supply, bus board, enclosure | Where a product bonds its 0 V to its chassis or to a protective-earth terminal, the bond shall be a conductor of at least 14 AWG, or copper of its own board of that section, landed by a ring terminal, a bracket, or a standoff on an M4 or larger stud or screw that presses metal GND-004 accepts under a toothed lock washer, or a bus bar of equivalent section. | inspection | A bond through paint or a loose terminal is a bond only until it corrodes; a toothed washer on metal that conducts keeps it low impedance for the life of the case, whether the bond arrives on a wire or on the board's own copper. |
6.2 Power supplies
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-SUP-001 | power supply | A power supply shall publish its ripple and noise on each rail it provides, peak-to-peak, measured as stated in clause 6.2. | measurement: ripple and noise per rail, peak-to-peak, by the 6.2 method | A ripple figure taken one stated way lets a buyer compare supplies and pick a quiet one for video or audio work. |
| EIS-SUP-002 | power supply | A power-supply output on a plug-and-socket connector other than a power header shall not mate with reversed polarity; a power-header outlet meets the marking and keying of clause 6.4 instead. | inspection | A supply connected backwards reverses every rail on the bus and can damage every module in the row at once. |
| EIS-SUP-003 | power supply | A power-supply output on row wiring terminals shall mark each terminal with its rail or 0 V. | inspection | Ring terminals on studs cannot be keyed, so a clear marking is the only guard against wiring a rail to the wrong place. |
| EIS-SUP-004 | power supply | Each output rail of a power supply shall survive an indefinite short to 0 V without damage, and shall return to its rated output when the short is removed, after an input cycle if it latches off. | measurement: each rail shorted to 0 V for at least 1 h, one rail at a time, then the short removed: no damage, and the rail returns to its rating | A short from a miswired ribbon or bus board is a routine fault, and the supply has to outlast it until someone finds it. |
| EIS-SUP-005 | power supply | During power-up, power-down, or a short on another rail, no output rail of a power supply shall be driven more than 0.7 V toward the opposite polarity. | measurement: each rail's swing past 0 V, at power-up, at power-down, and with the other rail shorted to 0 V, with a resistive load between +12 V and −12 V drawing the smaller rail's rated current | A rail pulled past 0 V reverse-biases every module's decoupling and the substrate of every IC on it; 0.7 V is a silicon diode's drop at modest current, and a Schottky clamp across each rail holds it at rated current. |
| EIS-SUP-006 | power supply | At start-up, no output rail of a power supply shall overshoot its nominal voltage by more than 10 %. | measurement: overshoot of each rail at start-up, at most 10 % of nominal | Parts on modules are chosen for the rails they run from, and a large start-up overshoot eats the voltage margin they were sized with. |
| EIS-SUP-007 | power supply | Each output rail of a power supply shall have ripple and noise below the limit tabulated in clause 6.2 for its power interface, 150 mV peak-to-peak on PWR-BUS, measured as clause 6.2 states. | measurement: ripple and noise per rail below the limit of its power interface, by the 6.2 method | A 150 mV ceiling gives modules a worst case to design against, at a level most open-frame switching supplies already meet. |
| EIS-SUP-010 | power supply | Each output rail of a power supply shall stay within ±5 % of its nominal voltage at its output terminals, from the minimum load the supply publishes on each rail to its rated current, whatever the load on its other rails within those limits. | measurement: each rail's voltage at its output terminals at its published minimum load and at its rated current, with the other rails at each end of theirs | A module's regulators, references, and patch levels are designed for ±12 V and +5 V; a rail 10 % off conforms to nothing else in EIS, and a cross-regulated supply drifts that far when one rail is lightly loaded. |
| EIS-SUP-008 | power supply | A power supply mounted on the product it powers shall publish the heat it dissipates at its rated output and how far it extends behind that product. | inspection | A linear regulator turns the difference between its input and output into heat in the case, and it adds to the depth of the module it sits behind; the installer budgets both (Annex H, ENC-001). |
| EIS-SUP-009 | power supply | A power supply may provide the 12 V DC rail of clause 8.1 alongside or instead of the bus; it then has PWR-DC12 outlets, publishes the current of each outlet, and meets the outlet rules of clause 8.1. | inspection | A case supply that gives a DC rail directly saves a brick per module, and its outlets keep the rules of 8.1 like any other PWR-DC12 outlet. |
6.3 Grounding and 0 V
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-GND-001 | module, power supply, bus board, enclosure | A product shall connect every 0 V pin of its power headers, and the −V of its DC entry, to its 0 V. | inspection | The 0 V pins share the return current of all three bus rails, and using only some crowds it onto fewer contacts; with the DC rail's −V on the same 0 V, a product keeps one reference for its signals whichever entry is connected. |
| EIS-GND-002 | bus board | A bus board shall join the 0 V pins of every header to one 0 V that runs to the supply's 0 V terminal. | inspection | One 0 V back to the supply terminal gives every module in the row the same reference and a defined path for return current. |
| EIS-GND-003 | power supply | A power supply shall publish whether its 0 V output is connected to protective earth, and where. | inspection | A system wants one bond between 0 V and protective earth; a second bond lets mains-frequency current flow in 0 V as hum. |
| EIS-GND-004 | module, power supply, bus board, enclosure | Where a product makes a bond of a metal part to its 0 V, to its CHASSIS terminal, or to another metal part, and publishes it as a bond, the fastener shall press bare, plated, or conversion-coated metal, or a copper land clear of solder mask, not paint, powder coat, anodizing, or solder mask, and the bond shall measure at most 100 mΩ, and a bond of 0 V to the chassis (PWR-008) at most 10 mΩ. | measurement: four-wire resistance at 1 A or more between the two parts, after assembly; this does not replace the protective-bonding test of the safety standard a mains product is certified to | A finish either conducts under a fastener, at a few milliohms, or is a dielectric, so a bond through paint or anodize is only a scratch. 100 mΩ, the protective-bonding figure of IEC 62368-1, is a pass mark every metal-to-metal joint clears by a factor of two or more, most by two orders, and every finished joint fails by five; the 0 V tie is held to 10 mΩ because a rail chafed onto the chassis returns its fault current through it. |
| EIS-GND-005 | enclosure | An enclosure shall publish which of its metal parts, rails, inserts, sides, rear, and lid, are bonded to one another, and where its metalwork takes a bond to the row's 0 V. | inspection | In the common case the chassis is the inserts and the panels, and the anodized rails float; the installer who straps a case needs to know which parts are already one and where the strap lands. |
6.4 The bus
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-BUS-001 | bus board, power supply (with a PWR-BUS outlet) | The bus shall provide +12 V and −12 V, and may provide +5 V, at every power header. | inspection | Every module may count on ±12 V at its header, while +5 V stays optional because many modules regulate their own. |
| EIS-BUS-002 | module, bus board, cable, power supply (PWR-BUS) | A power header on a module or a bus board shall be a 2 × 5 or 2 × 8 pin header on a 2.54 mm grid, and a power cable shall end in IDC ribbon sockets that mate it, the socket at the bus-board end having as many positions as the header it mates. | inspection | Every Eurorack power ribbon and header in use has this form, so any conforming module and bus board connect without an adapter; a 10-position socket on a 16-pin bus header can be fitted one pin pair off and short +12 V to 0 V. |
| EIS-BUS-003 | module, bus board, cable, power supply (PWR-BUS) | A power header on a module, a bus board, or a cable shall follow the pinout of clause 6.4: −12 V on pins 1–2, 0 V on 3–8, +12 V on 9–10, and on a 16-pin header +5 V on 11–12, CV on 13–14, and gate on 15–16. | inspection | Ribbons and bus boards made to a different pin order put +12 V on a module's 0 V pins; one pinout prevents that. |
| EIS-BUS-004 | module, bus board, cable, power supply (PWR-BUS) | The marked conductor of a power ribbon cable shall be −12 V, and on a module, a bus board, or a power supply it shall lie at the −12 V end of the header. | inspection | A marked conductor tied to −12 V lets an installer orient a ribbon by eye at both ends, the only guide on an unshrouded header. |
| EIS-BUS-005 | module, bus board, cable, power supply (PWR-BUS) | A shrouded power header on a module or a bus board shall be keyed so that, viewed from the mating side with the −12 V end at the bottom, the key gap is on the right, and a keyed cable socket shall match it. | inspection | A key in one fixed position lets a keyed socket enter a shrouded header only the right way round, whoever made each part. |
| EIS-BUS-006 | module (with a PWR-BUS entry) | A module powered from the bus shall draw only +12 V and −12 V, and may also draw +5 V. | inspection | These are the only rails a conforming bus delivers, so a module that needs any other rail cannot run from a conforming row. |
| EIS-BUS-007 | module (with a PWR-BUS entry) | A module that uses neither +5 V nor bus CV or gate may use the 10-pin header. | inspection | Pins 11 to 16 carry nothing such a module uses, so the smaller header saves board space without losing any connection. |
| EIS-BUS-008 | module, power supply (with a PWR-BUS entry) | A module or a power supply shall not draw more than 1.5 A on any rail through one power header. | measurement: current on each rail through one header in operation, at most 1.5 A, the charging of its decoupling at power-up excluded | Each rail has two IDC contacts rated 1 A, and they share the current unevenly, up to about 2:1 through a short ribbon; 1.5 A keeps the busier contact at its rating. |
| EIS-BUS-009 | module, power supply (with a PWR-BUS entry) | A module or a power supply shall tolerate reverse polarity at its power header without damage. | measurement: no damage after a ribbon reversed at the module end, and a 16-pin ribbon also reversed at the bus end, from a bench supply current-limited to the module's published currents | A reversed ribbon is the commonest field fault; surviving it keeps one mistake from destroying a module. |
| EIS-BUS-010 | module (with a PWR-BUS entry) | A bus cable supplied with a module shall be keyed so that it enters a shrouded header only with the marked conductor on −12 V. | inspection | A keyed cable makes the shroud do its job, so the ribbon that ships with a module cannot be fitted backwards into a shrouded header. |
| EIS-BUS-011 | module | A header on a module that is not its power header shall either not mate a Eurorack power ribbon socket or tolerate one fitted to it, either way round, without damage. | inspection | Expander and link headers often share the power header's form, and a power ribbon fitted to one puts ±12 V on its signal pins. |
| EIS-BUS-019 | module, bus board, power supply (PWR-BUS) | A module, a bus board, and a power supply shall mark the −12 V end of each power header on the board. | inspection | The marked conductor of a ribbon can only be matched to the header when the board says which end is −12 V; on an unshrouded header the marking is the only guide. |
6.5 Bus boards
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-BUS-012 | bus board, enclosure, power supply (with a PWR-BUS outlet) | The per-header limit a bus board, a built-in bus board of an enclosure, or a power supply publishes for its power-header outlets shall not exceed 1.5 A per rail. | inspection | A header carries each rail on two IDC contacts of about 1 A, the same limit modules are held to under BUS-008. |
| EIS-BUS-013 | bus board (with a PWR-BUS outlet) | A bus board may split CV and gate into two regions. | inspection | A split lets one long bus board carry two separate CV and gate lines, each with its own transmitter. |
| EIS-BUS-014 | bus board, cable (PWR-BUS) | A link between two bus boards shall join CV to CV and gate to gate. | inspection | A crossed link would send pitch CV to gate listeners and gate pulses to oscillators on the next board. |
| EIS-BUS-015 | cable (PWR-BUS) | A power ribbon from a bus header to a module shall be no longer than 400 mm and shall use conductors of at least 28 AWG. | inspection | At the 1.5 A header limit a 400 mm, 28 AWG ribbon drops about 65 mV in a rail's two conductors and about 30 mV more in its contacts, under 1 % of 12 V; a longer or thinner ribbon eats further into the rails the module receives. |
| EIS-BUS-020 | bus board | A bus board may also distribute a DC rail or the video sync behind the panel; it then meets the rules of what it carries: the PWR-DC12 outlet rules of 8.1, or the video sync ports of 8.2. | inspection | One board behind the panel can carry the bus, the DC rail, and the video sync tree; each outlet and port on it stays under the rule written for its interface. |
| EIS-BUS-021 | bus board | A bus board may carry a 0 V strip: a band of its outer-layer 0 V plane left bare of solder mask along the board's length, with plated holes at its mounting-hole positions, on which a 0 V bus bar is clamped by screws through the bar and the holes; the strip's end holes take M4, and a ring terminal under an M4 screw of the strip or the bar is a 0 V terminal of the board. | inspection | A bar clamped on bare copper the length of the board puts every header's return and every link on one potential with no trace between them, and the strip's M4 holes, two rings on each, give a board in the middle of a chain the positions one stud cannot: its return and a link each way. |
| EIS-BUS-022 | bus board (with a PWR-BUS outlet) | A bus board that splits CV and gate into regions shall mark on the board, and publish, which headers lie in each region. | inspection | ASM-002 allows one transmitter per line up to a region split; the installer can keep to it only if the split is visible and published. |
6.6 Bus CV and gate
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-BUS-016 | module (with a PWR-BUS entry) | A module shall listen to or transmit bus CV or gate only when a jumper or switch on the module is set to do so. | inspection | The bus CV and gate lines are shared across a row, so a module left at its default never fights a transmitter or reacts to stray levels. |
| EIS-BUS-017 | module (with a PWR-BUS entry) | A module that drives or receives bus CV shall meet the BUS-CV limits of clause 6.6. | measurement: BUS-CV scale at the header into 10 kΩ, within ±0.3 %; listener input impedance at least 100 kΩ | Every listening oscillator follows the one bus CV line, so shared levels and impedances keep any transmitter and listener in tune. |
| EIS-BUS-018 | module (with a PWR-BUS entry) | A module that drives or receives bus gate shall meet the BUS-GATE limits of clause 6.6. | measurement: BUS-GATE high at least +4 V and low at most +0.5 V at the header into 4.7 kΩ; listener thresholds +3 V and +1 V | Shared thresholds and impedances let any module's gate on the bus register reliably at every listening module. |
7.1 Signals
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-SIG-001 | module | A module shall publish a port list naming, for every port, its signal class or unclassified, and for a video sync port its mode (8.2). | inspection | The port list tells a user which class and limits each jack meets, so a patch can be checked before it is made. |
| EIS-SIG-002 | module | A patch input shall withstand ±12 V indefinitely. | measurement: no damage after ±12 V from a source of 1 kΩ or less is held on each patch input | ±12 V is the most a bus rail or any conforming output (SIG-004) can put on a jack, so an input that withstands it survives any patch. |
| EIS-SIG-003 | module | A patch output shall withstand an indefinite short to 0 V or to another patch output. | measurement: no damage after each patch output is shorted to 0 V and to another output | Patching an output to 0 V or to another output is a routine mistake on a patch panel, and one cable must not destroy a module. |
| EIS-SIG-004 | module | A patch output shall not drive the patch tip beyond ±12 V. | inspection | Keeping outputs within ±12 V keeps them within what every patch input is built to withstand under SIG-002. |
| EIS-SIG-015 | module | A patch jack shall carry patched signals only: a module shall neither take nor give its video sync at a patch jack, and no patch jack shall list a format of clause 8.3. | inspection | The video sync is system cabling, not a patch: kept on the rear coaxial interface, it is never changed by patching, and no patch cable has to carry it. |
| EIS-SIG-018 | module, bus board, enclosure | A product that generates or locks to an external video sync shall take or give it at a video sync port on its rear. | inspection | The video sync is system cabling: at the rear, on the coaxial interface, it is wired once behind the panel and stays out of the patch field. |
| EIS-SIG-017 | module, bus board, enclosure, power supply | A jack inside the case shall not be a BNC jack: none at the rear of a module, on a bus board, or on a power supply. A BNC jack is on the outside of the case only, on a front panel or an enclosure's wall. | inspection | A BNC's bayonet sleeve needs room for fingers to grip and turn, which the space behind the panels and over a bus board lacks, and its height takes depth a ribbon or a module's board needs; an RCA jack mates with a push and an SMA with a few turns of a small nut. A facility video sync arrives at a BNC on the enclosure's wall and is wired inside to RCA or SMA. |
7.2 Signal classes
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-SIG-005 | module | A port shall meet the limits of the class it names, at the range it names: an output keeps its full-scale signal within the range's ceiling, and an input accepts the range's full swing without clipping. | measurement: the class's level, impedance, and thresholds at the claimed range, from the class table of 7.2 | One table of classes lets a patch between any two modules work at the levels both expect, and the range says which swing an output gives and an input takes. |
7.3 Video signals
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-SIG-009 | module (VIDEO) | A VIDEO input shall present 100 kΩ ±1 % to 0 V at the patch tip. | measurement: 100 kΩ ±1 % to 0 V at each VIDEO input | A high, tightly held input impedance takes a 75 Ω output at almost unity gain, so video levels match from module to module. The figure is the resistance at the tip, resistor and stage together; a 1 % resistor costs what a 10 % one does. |
| EIS-SIG-010 | module (VIDEO) | A VIDEO output shall drive the patch tip through a 75 Ω ±1 % series resistor. | measurement: 75 Ω ±1 % series resistor from the buffer output to the tip of each VIDEO output | A 75 Ω series source keeps a short unterminated patch cable from ringing, and one fixed value keeps level and edges alike from module to module. |
| EIS-SIG-019 | module (VIDEO) | A VIDEO input that reads a signal as high or low, such as a comparator, logic, or key input, shall switch at a threshold of +0.5 V: it reads above the threshold as high and below it as low. | measurement: the input reads +0.45 V as low and +0.55 V as high | +0.5 V is the midpoint of the 0 to +1 V VIDEO scale, so any VIDEO output, a picture, a ramp, or another module's logic, drives any VIDEO logic input the same way, and a key or comparator splits a picture at mid-gray. |
| EIS-SIG-016 | module (VIDEO) | A module shall publish, for each VIDEO output, the kind of path behind it and, for a linear or variable path, its −3 dB bandwidth measured as clause 7.3 states. | measurement: the −3 dB bandwidth of each linear or variable VIDEO path, relative to 100 kHz, from a 75 Ω source into 100 kΩ in parallel with 30 pF, by a method of Annex A | The kind says whether a bandwidth describes the path, and the figure, measured one way, says how sharp a picture it passes. EIS sets no minimum: a slow path is a design choice, and the figure says so. |
Part 3 Optional interfaces
8.1 12 V DC power (PWR-DC12)
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-DC-001 | module, bus board, enclosure, power supply (with a PWR-DC12 entry) | A product shall publish its DC entry variant: DC-BAR21, DC-BAR25, DC-VH2, DC-DIN4, DC-MF6, or DC-MF8, as tabulated in 8.1. | inspection | The variant tells a buyer which plug, cable, and distribution product will physically mate with the product. |
| EIS-DC-002 | module, bus board, enclosure, power supply (with a PWR-DC12 entry) | A product shall publish the minimum and maximum DC input voltage its DC entry accepts. | inspection | Nominal 12 V adapters vary in output, so the accepted range tells a buyer which adapters the product can safely use. |
| EIS-DC-003 | module, bus board, enclosure, power supply (with a PWR-DC12 entry) | A DC entry shall not use the pinout of a Eurorack 10-pin or 16-pin power header. | inspection | A DC entry wired like a bus header invites a bus ribbon to be plugged into it, putting 12 V across the wrong pins. |
| EIS-DC-004 | module, bus board, enclosure, power supply (with a PWR-DC12 entry) | A DC-BAR21 or DC-BAR25 barrel DC entry shall be center positive. | inspection | Center positive is the usual convention of 12 V adapters, so fixing it keeps a common adapter from reversing the DC rail. |
| EIS-DC-005 | module, bus board, enclosure, power supply (with a PWR-DC12 entry) | A product with a DC-VH2, DC-DIN4, DC-MF6, or DC-MF8 DC entry shall implement the pin functions tabulated for that variant in 8.1. | inspection | Fixed pin functions let any cable or distribution product of that variant deliver +V and −V to the right pins. |
| EIS-DC-006 | module, bus board, power supply, enclosure (with a PWR-DC12 entry) | A barrel DC entry, and every case DC entry, shall tolerate reverse polarity without damage. | measurement: no damage after a reversed input at the entry's rated voltage, from a source current-limited to its rated current | Center-negative adapters fit the same barrel, and a computer supply's 8-pin EPS12V cable is a Mini-Fit Jr 2 × 4 like DC-MF8 with its +12 V on the other row; a reversed plug must not damage the product. |
| EIS-DC-007 | cable (PWR-DC12) | A straight DC barrel cable shall connect tip to tip and sleeve to sleeve at both ends. | inspection | A straight cable has to keep the center-positive polarity of both ends, or it reverses the DC rail it carries. |
| EIS-DC-008 | cable (PWR-DC12) | A cable for a DC-VH2, DC-DIN4, DC-MF6, or DC-MF8 DC entry shall connect each pin to the same pin and function at both ends. | inspection | Pin-for-pin wiring keeps +V and −V where the far end expects them, so the cable never reverses or shorts the DC rail. |
| EIS-DC-009 | module, bus board, power supply, enclosure (with a PWR-DC12 outlet) | A product with PWR-DC12 outlets to modules shall feed them only through DC-BAR21 jacks or DC-VH2 headers, and shall not use DC-BAR25 for an output to a module. | inspection | A DC-BAR25 plug enters a DC-BAR21 entry with unreliable contact, so outputs to modules use only connectors that fit module entries properly. |
| EIS-DC-010 | cable (PWR-DC12) | A cable from a PWR-DC12 outlet to a module shall end in DC-BAR21 plugs or DC-VH2 housings and connect +V to +V and −V to −V, tip and pin 1 being +V. | inspection | Module entries are center positive with pin 1 at +V, so a distribution cable has to keep that polarity at both ends. |
| EIS-DC-011 | module, bus board, enclosure, power supply (PWR-DC12) | A DC entry and each PWR-DC12 outlet shall be marked beside it with its polarity, a barrel by its polarity symbol and a multi-pin entry by its +V and −V pins, its nominal voltage, and its maximum current, and a DC entry also with the minimum and maximum input voltage it accepts. | inspection | An adapter is chosen at the entry and a cable at the outlet, so the marking beside the port is what keeps a wrong adapter or an overloaded outlet off a product. |
| EIS-DC-012 | module, bus board, power supply, enclosure (with a PWR-DC12 outlet) | A product with PWR-DC12 outlets to modules shall protect each output separately and shall publish the current at which the protection acts. | inspection | One shorted cable on an unprotected output takes every module on the rail down; a limit per output keeps the fault to one module. |
| EIS-DC-013 | module, bus board, power supply, enclosure (with a PWR-DC12 outlet) | A DC entry that feeds PWR-DC12 outlets shall tolerate reverse polarity without damage and shall not pass the reversed voltage to its outlets. | measurement: no damage after a reversed input, and no reversed voltage at any outlet | An entry that feeds a row is plugged by whoever assembles the case; a reversed adapter must not take the row with it. |
| EIS-DC-014 | module, bus board, power supply, enclosure (with a PWR-DC12 entry) | A product with a case DC entry, a DC entry that takes an external adapter's output for a row: any DC entry of an enclosure, a power supply, or a bus board, or of a module with PWR-DC12 outlets or row wiring outputs, shall publish whether its 0 V is bonded to the chassis at the entry, and where. | inspection | The case DC entry is where a system fed from an adapter makes its one chassis tie; an installer who cannot tell whether the entry bonds 0 V to the chassis either leaves the case floating or ties it twice. |
8.2 Video on 75 Ω coaxial jacks (VID-75)
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-V75-001 | module, bus board, enclosure (VID-75) | Every jack in a VID-75 tree shall be an RCA, BNC, or SMA jack. | inspection | The three jack types are electrically the same here, so any 75 Ω cable with the matching plugs joins any two products. |
| EIS-V75-002 | module, bus board, enclosure (VID-75) | On every jack in a VID-75 tree, the center pin shall carry the video signal and the shell shall be 0 V. | inspection | One center and shell convention lets any coaxial cable carry the signal and join the 0 V of the products it connects. |
| EIS-V75-003 | module, bus board, enclosure (VID-75) | A COAX-OUT or a buffered COAX-THRU shall drive one COAX-IN load, and an output shall not be split passively to several terminated ports. | inspection | A second termination on one output drops the level to two thirds and a third drops it to half. |
| EIS-V75-004 | cable (VID-75) | A VID-75 cable shall be a 75 Ω coaxial cable, with RCA, BNC, or SMA plugs, that connects center pin to center pin and shell to shell at both ends. | measurement: cable impedance 75 Ω; center to center and shell to shell at both ends | A 75 Ω cable keeps the line impedance continuous from source to termination, so the tree stays matched and free of reflections. |
| EIS-V75-006 | module, bus board, enclosure (with a COAX-IN) | A product with a video sync input shall take the video sync at a COAX-IN on its rear, lock any video timing of its own to it, and list the formats it accepts. | measurement: the module's video timing follows the video sync at its COAX-IN in each listed format | A COAX-IN says what a buyer needs to know first: this module follows the row's video sync, through this rear port, in these formats. |
| EIS-V75-007 | module, bus board, enclosure (with a COAX-OUT) | A product with a video sync output shall generate video sync of a listed format itself and give it at a COAX-OUT on its rear; a copy of the video sync it takes at its COAX-IN is a COAX-THRU, not a COAX-OUT. | measurement: video sync of each listed format at the COAX-OUT, with nothing connected at the COAX-IN | An output means the module can be the row's video sync; a THRU cannot, and the two are easy to confuse on a panel marked OUT. |
| EIS-V75-008 | module, bus board, enclosure (with a COAX-THRU) | A product shall have a video sync through only if it also has a video sync input, and each through shall be a COAX-THRU marked THRU. Its port list shall say which kind: buffered (a copy of the video sync at the COAX-IN, driven as a COAX-OUT into one COAX-IN load) or looped (a jack bridged to the COAX-IN jack on one line). | measurement: buffered: the video sync at the COAX-IN appears at the COAX-THRU at line level into 75 Ω; looped: the THRU jack is the COAX-IN line; the mark THRU beside the port | A THRU chains video sync through modules without a distribution product. Buffered, each THRU drives the next input; looped, one cable run passes every module with one termination at its end. The mark keeps either from being cabled as a source. |
| EIS-V75-009 | module, bus board, enclosure (with a COAX-THRU) | A product with a looped COAX-THRU shall give its COAX-IN a termination switch, marked TERM, that presents 75 Ω to 0 V across the line when on and no load when off, and shall lock the same with the switch on or off. | measurement: 75 Ω to 0 V across the line with TERM on, no load with TERM off; the module locks either way | A looped line is terminated once, at its far end; the switch is what lets the last module on the run terminate it and every other module bridge it. |
| EIS-V75-010 | module, bus board, enclosure (VID-75) | Every video sync port shall be a COAX-IN (75 Ω ±5 % to 0 V at the jack), a COAX-OUT (a 75 Ω ±5 % series source driven at twice the line level), or a COAX-THRU, buffered or looped, never a patch jack. | measurement: 75 Ω ±5 % to 0 V at each COAX-IN; twice the line level open-circuit, from 75 Ω ±5 %, at each COAX-OUT | The video sync tree works only when every port in it is terminated once and driven once; the port modes say what each jack does. A picture port on the front is listed in the port list by its Annex C class. |
| EIS-V75-011 | module, bus board, enclosure (VID-75) | A video sync port shall be marked beside it as an input (IN), an output (OUT), or a through (THRU), and a termination switch shall be marked TERM. | inspection | The installer cables the video sync once, behind the panel, and reads the marking, not the manual. |
| EIS-V75-012 | module, bus board, enclosure (VID-75) | A COAX-OUT port or a buffered COAX-THRU port shall pass the video sync with a −3 dB bandwidth of at least 30 MHz into a 75 Ω load. | measurement: −3 dB bandwidth of at least 30 MHz at each COAX-OUT and buffered COAX-THRU, into 75 Ω | A tri-level video sync edge is 54 ns ± 20 ns (SMPTE ST 274 and ST 296); a 30 MHz path keeps it inside that tolerance through a chain of buffered THRUs, and the buffers the trade uses for video sync distribution clear it with margin. |
8.3 Video timing
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-VID-001 | module, bus board, enclosure (VID-75) | A product's port list shall name, for each video sync input (COAX-IN) and output (COAX-OUT), every format of clause 8.3 the port accepts or generates, by its format ID. | inspection | Listing formats by ID on the video sync ports lets a buyer check that a video sync generator and the modules that lock to it share a format; a patch jack lists none, because it is never the video sync. |
| EIS-VID-002 | module, bus board, enclosure (VID-75) | For each format a port lists, the video timing a product generates at a COAX-OUT, and the video timing it locks to at a COAX-IN, shall match the format's publication within the tolerances that publication states; for a progressive format, and along the line for a high-definition interlaced format, the row of clause 8.3 is that publication's raster, sample for sample. | measurement: line and frame timing and the video sync structure of each listed format, within the publication's tolerances | Two products locked to one format have to agree on its raster. An analog interlaced format can be held only to its publication's tolerances, not to a clock-exact row; a sample-defined format is exact. |
Part 4 Assembly
9 Assembling a system
| ID | Applies to | Requirement | Verified by | Why |
|---|---|---|---|---|
| EIS-ASM-001 | installer | A module shall be added to a row only while, on each rail of each power interface, the sum of the published currents stays within the published totals of every source and every product with outlets that feeds it, and the current through each outlet stays within that outlet's limit. | inspection | Exceeding a bus board, header, or supply rating overheats contacts or trips the supply; the published currents exist so it can be checked first. |
| EIS-ASM-002 | installer | At most one module shall transmit on each CV line and at most one on each gate line, where a line runs across linked bus boards up to a region split. | inspection | Two transmitters on one line drive against each other, leaving a level that is neither and stressing both outputs. |
| EIS-ASM-003 | installer | Installation shall connect only one of a product's alternative power entries at a time. | inspection | Two sources on one product can feed current from one into the other through its power circuit. |
| EIS-ASM-004 | installer | Installation shall not insert a DC-BAR25 plug into a DC-BAR21 DC entry. | inspection | A DC-BAR25 plug enters a DC-BAR21 entry but makes unreliable contact, which can run hot or drop power under load. |
| EIS-ASM-005 | installer | Each DC rail shall be fed from one adapter or one case DC entry at a time. | inspection | Two adapters or entries on one DC rail fight each other's regulation and can feed current back into each other. |
| EIS-ASM-006 | installer | A DC-VH2, DC-DIN4, DC-MF6, or DC-MF8 DC entry shall be mated only with that variant's plug. | inspection | Each multi-pin variant has its own pin functions and contact rating, so only its own plug puts +V and −V on the right pins at its rated current. |
| EIS-ASM-007 | installer | Each video sync tree in a row shall have exactly one source, a COAX-OUT or an external video sync at one COAX-IN, and each COAX-IN shall be fed by one output. | inspection | Two sources on one tree fight; an input fed by two outputs has two drivers on one line. |
| EIS-ASM-008 | installer | Row wiring an installer adds between a power supply, bus boards, a DC entry, or PWR-DC12 outlets shall meet PWR-006 and PWR-007, with each ring terminal clamped on the product's M4 terminal under a lock washer, and a bond an installer adds shall meet PWR-008. | inspection | A supply and a bus board from different makers are joined by the installer; the wiring rules travel with the installer, not with either product. |
| EIS-ASM-009 | installer | Where the bus boards of one enclosure are fed by more than one power supply, installation shall link their 0 V so that every bus board reaches, directly or through other boards' links, a bus board fed by each other supply, each 0 V link at most 2 mΩ terminal to terminal, and each bus board shall keep its own 0 V conductor to the supply that feeds it. | measurement: four-wire resistance of each 0 V link, terminal to terminal, at 20 to 25 °C | Two supplies joined only at their outputs put the drop of each one's conductors between two rows' references; a link between the bus boards holds every board's 0 V at one potential whatever each return carries. Hinton Instruments runs one common 0 V bar and links cases at under 2 mΩ for the same reason; between cases the 2 mΩ cannot be held past about 0.44 m on 10 AWG, so there EIS recommends the link instead. |