Annex E (informative) — Row budget
A planning worksheet for one row, with a schema and a validator. EIS does not require an enclosure to publish it. The rows behind it are ENC-001 (width and clear depth), PWR-001 and PWR-002 (the currents each power entry and outlet publishes, 6.1), BUS-012 (a bus board's per-header limit), SUP-001 (supply ripple), and ASM-001 (the installer's sum).
A row is budgeted per power interface (6.1): the bus and PWR-DC12, each where a source of that interface feeds modules in the row. Each interface's sources are listed with their totals (+12 V, −12 V; +5 V optional on the bus; 12 V: one +V and −V pair on PWR-DC12), and each module with its draw on each interface it uses.
The row
| Field | Source |
|---|---|
| Row id or name | Maker |
| Width (HP) | ENC-001 |
| Clear depth behind the panel (mm) | ENC-001 |
| Video sync distribution | None, or VID-75 (a coaxial tree) |
Sources, one line each, per power interface
| Field | Source |
|---|---|
| Power interface | PWR-BUS or PWR-DC12 (6.1) |
| Source | Bus board, supply, or a product with PWR-DC12 outlets |
| Total on each rail of the interface (A) | PWR-002 |
| Outlets, and the limit at each (A); a bus board header at most 1.5 A per rail | PWR-002, BUS-012 |
| Ripple and noise, mV peak-to-peak (a supply) | SUP-001 |
Modules
| Field | Source |
|---|---|
| HP and depth | PANEL-003 |
| Draw on each power interface and rail (A) | PWR-001 |
On each power interface and rail, the modules' sum stays within every source on that interface, and each module's draw within the limit of its outlet (ASM-001). For a module that publishes no −12 V current, 9.1 recommends planning 50 % of its +12 V current.
Machine-readable example
data/examples/row_budget_two_row.yaml describes a two-row instrument; data/row_budget.schema.json is its schema. Check it with:
python tools/row_budget.py --check data/examples/row_budget_two_row.yaml