Annex I (informative) — Worked examples

Three products taken from first sketch to claim, to show how the clauses fit together, and five cases wired as 6.1 and 6.3 ask. The figures are illustrative. Each product example has a claim file in data/examples/ that eis claim accepts.

I.1 A module: a two-channel video mixer

EIS · Worked example: a two-channel video mixer, from panel to claim IN A · VIDEO IN B · VIDEO MIX CV · CV U1 OUT · VIDEO · BW45, 12 ns INV OUT · VIDEO · BW40, 15 ns 8 HP claim EIS draft, module size 3U, 8 HP, 28 mm deep +12 V 0.12 A −12 V 0.06 A +5 V 0 A, 10-pin header ports 5, each with a class heat 2.2 W at most From data/examples/claim-module-video-mixer.yaml.

Step Decision Requirement
1. Size 3U, 8 HP: a panel 128.5 mm high and no wider than 40.64 mm, made 40.34 mm; four Ø3.2 mm holes on the hole grid PANEL-002, PANEL-006, PANEL-010, PANEL-011
2. Board 28 mm deep behind the panel, and 9.25 mm clear of the top and bottom edges PANEL-003, PANEL-012
3. Power Publishes 0.12 A on +12 V, 0.06 A on −12 V, and 0 on +5 V; it uses neither +5 V nor bus CV or gate, so a 10-pin header is enough PWR-001, BUS-007
4. Protection Survives a reversed ribbon; every 0 V pin of the header is tied to the board's 0 V BUS-009, GND-001
5. Ports IN A and IN B: VIDEO inputs, 100 kΩ. OUT and INV OUT: VIDEO outputs through 75 Ω. MIX CV: CV at U1, the 0 to +1 V scale of VIDEO. All five go on the port list SIG-001, SIG-005, SIG-009, SIG-010
6. Patch safety Every input survives ±12 V; every output survives a short and never drives beyond ±12 V SIG-002, SIG-003, SIG-004
7. Video paths OUT and INV OUT are linear paths from IN A, published as BW45 and BW40. As EIS recommends, it also publishes the measuring method, Method A of Annex A, the delays, 12 ns and 15 ns, and 22 pF at each input SIG-016, 7.3
8. Claim A module; its power header is a PWR-BUS entry of Core: EIS draft, module claim-module-video-mixer.yaml

It dissipates at most 12 V × 0.12 A + 12 V × 0.06 A = 2.2 W (Annex H).

I.2 A case: two rows with a built-in supply

A desktop case with two 104 HP rows, each 55 mm deep behind the panel; a built-in supply rated 4.0 A on +12 V, 2.0 A on −12 V, and 2.0 A on +5 V; and a built-in bus board with 28 headers and a 1.5 A per-header limit.

Step Decision Requirement
1. Rows Publishes 104 HP and 55 mm for each row, so a 28 mm module fits and a 60 mm one does not ENC-001, PANEL-003
2. Rails Rails of the recommended section with M3 inserts; ships 6 mm M3 screws and states their length RAIL-003, RAIL-009, RAIL-011
3. Supply Publishes each rail's rating and ripple: 10 mV, 10 mV, and 15 mV, all below 150 mV. Marks each terminal with its rail; survives a short on any rail; swings no more than a diode drop toward the opposite polarity, and overshoots by no more than 10 % at start-up PWR-002, SUP-001 to SUP-007
4. Bus board Publishes its totals and the 1.5 A per-header limit; every header's 0 V runs to the supply's 0 V PWR-002, BUS-012, GND-002
5. Earth Its 0 V is bonded to the chassis at the built-in supply's earth terminal, by a 14 AWG strap to a bare pad, and the chassis to protective earth at the IEC inlet; the documentation says so GND-003, PWR-008
6. Row wiring 14 AWG from the supply's M4 terminals to each bus board, the 0 V carrying the larger of 4.0 + 2.0 A and 2.0 A, 6 A PWR-005 to PWR-007
7. Claim It plays three roles: EIS draft, enclosure + power supply + bus board (4.2) claim-enclosure.yaml

Whoever fills a case then budgets each row (9.1). row_budget_two_row.yaml does so for a separate example instrument, not the case above: two 84 HP rows, each with its own bus board and supply.

Row +12 V −12 V PWR-DC12 Heat (Annex H)
Performance 0.58 A 0.375 A, the MIDI utility's unpublished −12 V current planned at half its +12 V current — about 11.5 W
Processing 1.03 A 0.50 A 1.6 A about 37.6 W

EIS · A row's current budget on the bus: the example row 'performance' +12 V 0.58 A of modules, 3.42 A left bus board and supply 4 A −12 V 0.375 A of modules, 2.125 A left bus board and supply 2.5 A +5 V 0.00 A of modules, 2.00 A left bus board and supply 2 A Audio I/O: +12 V 0.12 A, −12 V 0.08 A Mixer: +12 V 0.18 A, −12 V 0.12 A VCO: +12 V 0.09 A, −12 V 0.05 A VCF/VCA: +12 V 0.08 A, −12 V 0.06 A Envelope/LFO: +12 V 0.06 A, −12 V 0.04 A MIDI utility (Type A): +12 V 0.05 A, −12 V not published A module goes into a row only while each rail's sum stays within the bus board's totals, its per-header limit, and the supply's rating (ASM-001). The dashed segment is the module with no published −12 V figure, planned at 50 % of its +12 V draw, as EIS recommends.

I.3 A video row: one video sync, one DC rail

EIS · Worked example: one video sync and one DC rail across a row video sync generator COAX-OUT video bus board COAX-IN, 8 buffered THRU SMA video module COAX-IN video module COAX-IN video module COAX-IN RCA DC entry panel DC-DIN4 entry, 8 × DC-BAR21 12 V adapter DC-BAR21 to each module, each outlet protected (DC-012) One source per tree (ASM-007); each module on one of its power entries at a time (ASM-003); shells and −V are 0 V (V75-002, GND-001).

Step Part and claim What it does in the row
1. Generate Video sync generator, module, claim-module-video-sync-generator.yaml Its VIDEO SYNC OUT, a COAX-OUT on SMA, drives the bus board's VIDEO SYNC IN
2. Distribute Video bus board, bus board, claim-bus-board-video-sync.yaml Takes the video sync at VIDEO SYNC IN, a COAX-IN, and gives each module a buffered copy at a COAX-THRU
3. Lock Video modules, module Each takes the video sync at a rear COAX-IN on RCA or SMA; no BNC is inside the case (SIG-017)
4. Power DC entry panel, module, claim-module-dc-entry.yaml Takes 12 V at a DC-DIN4 case entry and feeds modules at DC-BAR21 outlets, each protected
5. Cable cable mating VID-75 or PWR-DC12 Coaxial cables center to center and shell to shell (V75-004); DC cables +V to +V and −V to −V (DC-010)
6. Install The installer One source per tree (ASM-007); each dual-source module connected to one source (ASM-003)

Every coaxial shell, and the DC rail's −V, is the modules' 0 V (V75-002, GND-001), so the video sync, the picture, and the power share one 0 V. With the DC adapter floating and one earth bond at the case supply, there is no ground loop to show as hum bars (6.3).

I.4 Power distribution: five cases wired

Every conductor of row wiring in five cases, with its gauge and length, its resistance and drop, and the rule it meets. The resistances are the row wiring table's figures (6.1): stranded copper at 1.05 times the solid figure, plus 0.25 mΩ for each crimp and its bolted joint. Every ring terminal sits on an M4 terminal under a lock washer (PWR-005). The tables are generated from data/distribution_examples.json, and the generator refuses an example that breaks a rule.

EIS · Four rows from two supplies: one entry, two stars of returns, three links, one tie bus board 1 bus board 2 bus board 3 bus board 4 DC-MF8 entry 28 A CHASSIS supply 1 supply 2 12 AWG · 150 mm +12 V and 0 V, two rings per stud 12 AWG · 350 mm +12 V and 0 V 16 AWG · 250 mm for each rail and 0 V, to each board 16 AWG · 250 mm for each rail and 0 V, to each board 12 AWG · 180 mm 0 V links ASM-009 12 AWG · 180 mm strap, 14 AWG · 100 mm to a bare pad on the case side Two supplies, two stars: each board's 0 V returns to its own supply (GND-002); the links hold the four boards at one reference (ASM-009); the entry's studs take one lead per supply, two rings each. One tie, at the entry's CHASSIS stud (DC-014); both supplies publish their 0 V as floating from the case. The table in Annex I.4 gives every conductor's resistance and drop.

One row from a DC adapter

A 3U, 84 HP desktop case in wood with anodized rails and steel M3 strips. A 12 V, 5 A desktop adapter plugs into a DC-DIN4 case DC entry panel at the left end of the row; a 48 W-class supply (2.6 A on +12 V, 1.0 A on −12 V, 1.0 A on +5 V) sits behind the row beside the entry; one bus board runs the row, its inlet terminals at mid-row.

The DC entry panel bonds 0 V to its panel through a 0 Ω link and carries the M4 CHASSIS stud; the case is wood and the rails anodized, so the chassis is the steel strips and whatever panels are bare under their screw heads, and no strap is needed (6.3). The adapter floats.

Conductor Carries Gauge Length Resistance Drop Meets Or
entry +12 V to supply +12 V in 5 A 16 AWG or 1.5 mm² 150 mm 2.6 mΩ 13 mV PWR-006, 16 AWG up; PWR-007, 5 mΩ —
entry 0 V to supply 0 V in 5 A 16 AWG or 1.5 mm² 150 mm 2.6 mΩ 13 mV PWR-006, 16 AWG up; PWR-007, 5 mΩ —
supply +12 V to bus board +12 V 2.6 A 16 AWG or 1.5 mm² 300 mm 4.6 mΩ 12 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ 18 AWG would be 7.1 mΩ: fails
supply −12 V to bus board −12 V 1 A 16 AWG or 1.5 mm² 300 mm 4.6 mΩ 5 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply +5 V to bus board +5 V 1 A 16 AWG or 1.5 mm² 300 mm 4.6 mΩ 5 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply 0 V to bus board 0 V 3.6 A 16 AWG or 1.5 mm² 300 mm 4.6 mΩ 17 mV PWR-006, 16 AWG up; PWR-007, 5 mΩ; 0 V no higher than its rails —

Two rows from one supply

A 6U, 104 HP case in powder-coated aluminum with bare pads where the rails meet its sides, so the sides, rails, and strips are one chassis (GND-005). A DC-DIN4 case DC entry at the left feeds a 100 W-class supply (6.0 A on +12 V, 2.5 A on −12 V, 2.0 A on +5 V, 112 W out, about 11 A in at 85 % efficiency) mounted between the rows at the left end; each row has its own bus board with its inlet at mid-row, 250 mm from the supply for the upper row and 400 mm for the lower.

The tie is the DC entry panel's CHASSIS stud. A strap from it to the nearest bare pad on the case side bonds the metalwork; the supply's 0 V is not bonded to the case anywhere else, and the supply publishes that.

Conductor Carries Gauge Length Resistance Drop Meets Or
entry +12 V to supply +12 V in 11 A 12 AWG or 4 mm² 200 mm 1.6 mΩ 18 mV PWR-006, 12 AWG up; PWR-007, 5 mΩ —
entry 0 V to supply 0 V in 11 A 12 AWG or 4 mm² 200 mm 1.6 mΩ 18 mV PWR-006, 12 AWG up; PWR-007, 5 mΩ —
supply +12 V to upper board 3 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 12 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ 18 AWG would be 6.0 mΩ: fails
supply −12 V to upper board 1.25 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 5 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply +5 V to upper board 1 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 4 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply 0 V to upper board 4 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 16 mV PWR-006, 16 AWG up; PWR-007, 5 mΩ; 0 V no higher than its rails —
supply +12 V to lower board 3 A 14 AWG or 2.5 mm² 400 mm 4.0 mΩ 12 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ 16 AWG would be 6.0 mΩ: fails
supply −12 V to lower board 1.25 A 14 AWG or 2.5 mm² 400 mm 4.0 mΩ 5 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply +5 V to lower board 1 A 14 AWG or 2.5 mm² 400 mm 4.0 mΩ 4 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply 0 V to lower board 4 A 14 AWG or 2.5 mm² 400 mm 4.0 mΩ 16 mV PWR-006, 16 AWG up; PWR-007, 5 mΩ; 0 V no higher than its rails —
0 V link, upper board to lower board no load: a reference 12 AWG or 4 mm² 180 mm 1.5 mΩ — ASM-009, 2 mΩ —
strap, CHASSIS stud to the case side no load: a bond 14 AWG or 2.5 mm² 100 mm 1.4 mΩ — PWR-008, 14 AWG up —

Four rows from two supplies

A 12U, 104 HP case, four rows, two 100 W-class supplies, one DC-MF8 case DC entry rated 28 A at the left feeding both supplies in parallel, about 11 A each. Supply 1 sits between rows 1 and 2 and feeds their boards; supply 2 between rows 3 and 4 and feeds theirs. Each board's inlet is at mid-row, 250 mm from its supply.

One tie, at the DC entry: its CHASSIS stud, strapped to the case side. Both supplies publish their 0 V as floating from the case. Row wiring returns run as two stars, one per supply; the links between the boards hold the four rows at one reference (ASM-009).

Conductor Carries Gauge Length Resistance Drop Meets Or
entry +12 V to supply 1 +12 V in 11 A 12 AWG or 4 mm² 150 mm 1.3 mΩ 15 mV PWR-006, 12 AWG up; PWR-007, 5 mΩ —
entry 0 V to supply 1 0 V in 11 A 12 AWG or 4 mm² 150 mm 1.3 mΩ 15 mV PWR-006, 12 AWG up; PWR-007, 5 mΩ —
entry +12 V to supply 2 +12 V in 11 A 12 AWG or 4 mm² 350 mm 2.4 mΩ 27 mV PWR-006, 12 AWG up; PWR-007, 5 mΩ 14 AWG carries at most 8 A: fails PWR-006
entry 0 V to supply 2 0 V in 11 A 12 AWG or 4 mm² 350 mm 2.4 mΩ 27 mV PWR-006, 12 AWG up; PWR-007, 5 mΩ —
supply 1 +12 V to board 1 3 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 12 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply 1 0 V to board 1 4 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 16 mV PWR-006, 16 AWG up; PWR-007, 5 mΩ —
supply 1 +12 V to board 2 3 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 12 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply 1 0 V to board 2 4 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 16 mV PWR-006, 16 AWG up; PWR-007, 5 mΩ —
supply 2 +12 V to board 3 3 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 12 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply 2 0 V to board 3 4 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 16 mV PWR-006, 16 AWG up; PWR-007, 5 mΩ —
supply 2 +12 V to board 4 3 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 12 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply 2 0 V to board 4 4 A 16 AWG or 1.5 mm² 250 mm 4.0 mΩ 16 mV PWR-006, 16 AWG up; PWR-007, 5 mΩ —
0 V link, board 1 to board 2 no load: a reference 12 AWG or 4 mm² 180 mm 1.5 mΩ — ASM-009, 2 mΩ —
0 V link, board 2 to board 3 (the one ASM-009 requires) no load: a reference 12 AWG or 4 mm² 180 mm 1.5 mΩ — ASM-009, 2 mΩ —
0 V link, board 3 to board 4 no load: a reference 12 AWG or 4 mm² 180 mm 1.5 mΩ — ASM-009, 2 mΩ —
strap, CHASSIS stud to the case side no load: a bond 14 AWG or 2.5 mm² 100 mm 1.4 mΩ — PWR-008, 14 AWG up —

A rack frame with an AC inlet

A zinc-plated steel 19-inch rack frame, 3U, 84 HP, with an AC inlet on its rear panel and a linear bus supply (2.0 A on +12 V, 2.0 A on −12 V, 1.0 A on +5 V) on the rear panel too, 350 mm from the bus board's inlet at mid-row. The frame's plated steel bonds at every bolt.

The chassis is bonded to protective earth at the AC inlet, under the safety standard the supply is built to; 0 V meets the chassis at the supply's earth terminal, which the supply publishes (GND-003), on a strap to the frame. The DC side has no case DC entry, so there is no second tie.

Conductor Carries Gauge Length Resistance Drop Meets Or
supply +12 V to bus board +12 V 2 A 14 AWG or 2.5 mm² 350 mm 3.5 mΩ 7 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ 16 AWG would be 5.3 mΩ: fails
supply −12 V to bus board −12 V 2 A 14 AWG or 2.5 mm² 350 mm 3.5 mΩ 7 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply +5 V to bus board +5 V 1 A 14 AWG or 2.5 mm² 350 mm 3.5 mΩ 4 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ —
supply 0 V to bus board 0 V 3 A 14 AWG or 2.5 mm² 350 mm 3.5 mΩ 11 mV PWR-006, 18 AWG up; PWR-007, 5 mΩ; 0 V no higher than its rails —
bond, supply earth terminal to the frame no load: a bond 14 AWG or 2.5 mm² 80 mm 1.2 mΩ — PWR-008, 14 AWG up —

Two cases, each with its supply

Two desktop cases of the first example side by side, each with its own adapter, DC entry, supply, and bus board, patched together. Each case's bus board carries a second M4 0 V terminal for the link.

Each case has its own tie at its DC entry; the adapters float, so the two ties make no loop. Each case has its own supply, so EIS recommends a 0 V link between the two bus boards (6.3): 10 AWG or heavier, as short as the cases allow, at most 2 mΩ where it can be. ASM-009's 2 mΩ binds inside one enclosure; three or more cases link as a grid.

Conductor Carries Gauge Length Resistance Drop Meets Or
0 V link, case A bus board to case B bus board no load: a reference 10 AWG or 6 mm² 400 mm 1.9 mΩ — 2 mΩ, recommended between cases (6.3) 12 AWG would be 2.7 mΩ: fails