5.2.1 Front panels
A front panel is the plate on the front of a module, or a blank panel that fills unused width in a row. It screws to the rails through a rail insert.
A front panel shall be no more than 2.0 mm thick (PANEL-004). EIS recommends 5052 aluminum or FR-4 circuit board, 1.6 mm to 2.0 mm thick. FR-4 is less stiff, so an FR-4 panel needs extra mounting holes at a narrower width than aluminum (Extra mounting holes).
A front panel thinner than 1.6 mm shall ship with M3 mounting screws with a head at most 7.0 mm across, whose length fits the window of 5.3 for its own thickness on a rail of the section 5.3 recommends (PANEL-014). The enclosure's screws are sized for panels of 1.6 mm to 2.0 mm and can bottom out through a thinner one.
A patch jack shall be a 3.5 mm mono (TS) socket (PANEL-005). 7.1 recommends insulating jacks from the panel; the panel and 0 V says how.
A blank panel plays the panel role of 4.1 and meets the same height, width, thickness, and hole requirements as a module's panel.
The panel and 0 V
A panel makes two choices, and they are independent. A module shall publish both: whether its front panel is connected to its 0 V, and whether the panel is bonded to the rails (PANEL-015).
| Bonded to the rails (bare metal under the screw heads, 6.3) | Floating from the rails (coated or masked up to the holes) | |
|---|---|---|
| Insulated from 0 V (no jack sleeve, pot body, or switch frame reaches the panel) | The panel is chassis: it shields and drains static, and carries no signal. What EIS recommends for a metal panel. | The panel is inert. Fine; the usual result of an anodized panel or an FR4 panel masked everywhere. |
| Connected to 0 V (the panel bonded to the module's 0 V at a jack bushing or a screw, through bare metal, GND-004) | A 0 V to chassis tie at this module. With the system's tie at its power entry this is a second tie, and EIS recommends against it; only the product at the tie does this. | The Eurorack convention. The panel sits at the module's 0 V, and two panels butted edge to edge join two modules' 0 V through their bare cut edges; one butted against a chassis panel is a second chassis tie. Tolerable; the loops it makes are why EIS recommends insulating. |
EIS recommends the first row: a panel insulated from 0 V, bonded to the rails if it is metal and the maker wants a shield, floating otherwise. Insulated means that nothing at 0 V touches the panel: not a jack's sleeve, a pot's bushing, a switch's frame, or an encoder's body.
Insulated jacks on an FR4 panel
The usual 3.5 mm jack has a metal threaded bushing, about 6 mm across, a hex nut of 8 mm across the flats (9.2 mm across the corners) and a washer of about 9.5 mm. On an FR4 panel the board itself is the insulator, and the jack is insulated by keeping the panel's copper away from everything the jack touches:
- the hole is unplated (NPTH), to the jack's drawing, about 6.1 mm to 6.4 mm for a 6 mm bushing;
- no copper on any layer within a circle at least 1 mm beyond the nut's corners and the washer: Ø12 mm for the jack above, centered on the hole, so that the hole's bore, the nut, and the washer meet no copper;
- solder mask may run over the panel's copper up to the keep-out and across it; it is cosmetic, not the insulation: 15 µm to 30 µm of mask under a nut turned to torque may or may not be cut through, which is also why GND-004 refuses it as a bond surface;
- the same keep-out on the back face, where the jack's body sits; the usual jacks have plastic bodies, and a metal-cased jack or a pot's bushing needs the keep-out to cover whatever it touches.
The jack's sleeve is then at the module's 0 V on the board behind the panel and nowhere else, and the panel's copper is free to be bonded to the rails through finished lands at the mounting holes, or left floating.
Insulated jacks on a metal panel
A metal bushing through a bare metal panel is a connection, and through an anodized one it may or may not be: anodize in a hole's bore is thin, and a bushing turned into it cuts through or does not. To insulate a jack on a metal panel, use a jack whose bushing is plastic, or an insulating shoulder washer in an oversized hole with a flat insulating washer under the nut. Pots, switches, and encoders with metal bushings take the same treatment. Otherwise the panel is published as connected to 0 V, and EIS recommends that the connection be made a bond, bare metal under at least one bushing's nut or washer, rather than whatever a bushing scratches through anodize.
Height
| Format | Panel height | Hole span | Holes from panel center | Provenance |
|---|---|---|---|---|
| 1U | 39.65 mm | 33.65 mm | ±16.825 mm | inherited: Intellijel 1U |
| 3U | 128.5 mm | 122.5 mm | ±61.25 mm | inherited: Doepfer A-100 |
A 3U front panel shall be 128.5 mm high (PANEL-006): 4.85 mm under three rack units (133.35 mm), so it fits within the 132.55 ± 0.4 mm 3U height H1 of 5.1. The 4.85 mm is clearance, not a rail lip; where a rail has a lip, EIS recommends at most 1.5 mm (5.3).
A 1U front panel shall be 39.65 mm high (PANEL-007), the Intellijel 1U format, 4.80 mm under one rack unit. EIS defines no other panel height.
Mounting holes shall be 3.0 mm in from the top and bottom panel edges (PANEL-008). A panel that is to be chassis is bonded to the rails only by what is under its screw heads (6.3): EIS recommends a bare 7 mm disc at each hole on a coated panel, or a finished copper land on an FR4 one. The hole span is then the panel height less 6.0 mm, and it shall be 122.5 mm at 3U and 33.65 mm at 1U, the same on the panel and between the inserts of a row's two rails (PANEL-009).
Width
The nominal width of an N HP panel is N × 5.08 mm, where N is any positive whole number. An N HP panel shall be no wider than its nominal width (PANEL-002). EIS recommends making it 0.3 mm narrower, so that neighboring panels do not bind:
panel width = N × 5.08 − 0.3 mm
The board behind the panel is 0.6 mm under the nominal width (5.2.2). A rail gives at least the nominal width of its row (RAIL-002), so a row of panels at either width fits it.
| HP | Nominal (mm) | Panel (mm) | Board (mm) |
|---|---|---|---|
| 1 | 5.08 | 4.78 | 4.48 |
| 2 | 10.16 | 9.86 | 9.56 |
| 3 | 15.24 | 14.94 | 14.64 |
| 4 | 20.32 | 20.02 | 19.72 |
| 6 | 30.48 | 30.18 | 29.88 |
| 8 | 40.64 | 40.34 | 40.04 |
| 10 | 50.80 | 50.50 | 50.20 |
| 12 | 60.96 | 60.66 | 60.36 |
| 14 | 71.12 | 70.82 | 70.52 |
| 16 | 81.28 | 80.98 | 80.68 |
| 18 | 91.44 | 91.14 | 90.84 |
| 20 | 101.60 | 101.30 | 101.00 |
| 24 | 121.92 | 121.62 | 121.32 |
| 28 | 142.24 | 141.94 | 141.64 |
| 32 | 162.56 | 162.26 | 161.96 |
| 36 | 182.88 | 182.58 | 182.28 |
| 42 | 213.36 | 213.06 | 212.76 |
| 84 | 426.72 | 426.42 | 426.12 |
| 104 | 528.32 | 528.02 | 527.72 |
Mounting holes
Mounting holes shall be drilled Ø3.2 mm, or slotted 3.2 mm wide and no longer than 5.5 mm along the rail, centered on the hole position (PANEL-010). Either clears the M3 mounting screw; a short slot takes up a rail's position error without letting the panel drop.
Along the rail, each mounting hole shall be a whole number of HP plus 2.54 mm from the panel's nominal left edge (PANEL-011). The nominal edges are N × 5.08 mm apart and centered on the panel, so every hole meets a hole in the rail insert, whatever the panel's width and wherever it sits in the row. The top and bottom rows of holes are the same.
Measured from the panel center:
- an odd-HP panel has its holes a whole number of HP out, an even-HP panel a whole number of HP plus 2.54 mm;
- from 3 HP up, the outer holes are 7.62 mm in from each nominal edge, which puts the one hole of a 3 HP panel on its center;
- a 1 HP panel has one hole, on its center, and a 2 HP panel has its holes at ±2.54 mm.
The two cards below show an 8 HP panel.
Extra mounting holes
EIS sets no hole count; four holes are the usual pattern. A wide panel needs more so that a 10 N push at midspan, about the force of seating a plug, bows it no more than 0.5 mm between screws. On four screws a 3U panel reaches 41 HP in 1.6 mm 5052 and 26 HP in 1.6 mm FR-4, the most flexible recommended sheet; past that, a hole is added on each rail, a middle hole first, until every gap is inside the span. On an even-HP panel the middle hole sits 2.54 mm to one side of the center, on the hole grid.
The numbers are in data/module.json. tools/module.py derives the hole spans and widths and computes the extra-hole patterns; tools/cards_system.py draws the span card.