2 Normative references

EIS applies the following publications by dated reference; only the editions listed apply. Rack dimensions quotes the figures EIS takes from the IEC publications.

Designation Title Publisher Used by EIS for
IEC 60297-3-101:2004 Dimensions of mechanical structures of the 482,6 mm (19 in) series — Part 3-101: Subracks and associated plug-in units IEC HP (5.08 mm) and rack-unit height (44.45 mm), RACK-001 and RACK-002; flange width and the 84 HP row width for a rack-mount frame, RACK-003
IEC 60297-3-100:2008 Dimensions of mechanical structures of the 482,6 mm (19 in) series — Part 3-100: Basic dimensions of front panels, subracks, chassis, racks and cabinets IEC 3U front panel height H1, flange mounting-hole span H2 and end distance H3, the oval mounting slot, and the rack mounting grid, RACK-003
ISO 261:1998 ISO general purpose metric screw threads — General plan ISO M3 pitch and major diameter, RAIL-006 and RAIL-007
ITU-R BT.601-4 (1994) Encoding parameters of digital television for studios ITU The placement of the digital active line against OH for the interlaced SD formats, VID-002
SMPTE ST 170:2004 Composite analog video signal — NTSC for studio applications SMPTE 525i59.94 timing, VID-002
ITU-R BT.470-7 (2005) Conventional analogue television systems ITU 625i50 timing, VID-002
CTA-861-H (2021) A DTV Profile for Uncompressed High Speed Digital Interfaces CTA 480p59.94 and 576p50 rasters (video format timings 2 and 3, and 17 and 18), VID-002
SMPTE ST 296:2012 1280 × 720 progressive image 4:2:2 and 4:4:4 sample structure — Analog and digital representation and analog interface SMPTE 720p timings, VID-002
SMPTE ST 274:2008 1920 × 1080 image sample structure, digital representation and digital timing reference sequences for multiple picture rates SMPTE 1080-line rasters and digital timing reference sequences, VID-002
SMPTE ST 240:1999 Television — 1125-line high-definition production systems — Signal parameters SMPTE The analog tri-level video sync waveform, ±300 mV, behind the line level of 8.2, V75-010

data/video_timings.json names the publication behind each format. The raster figures of 8.3 agree with those publications and, where a row has a contract entry, with a hardware-verified timing contract, which tests/video_timings_contract.py checks.

Inherited conventions

EIS restates these conventions in its own words. The pages are not normative references, and a change to them does not change EIS; they are cited so that every inherited requirement in the register names its origin.

Source Retrieved Inherited by EIS
Doepfer, Construction Details A-100 2026-10-09 3U panel height 128.5 mm (PANEL-006), hole inset 3.0 mm (PANEL-008), hole drill Ø3.2 mm (PANEL-010), width and thickness ceilings (PANEL-002, PANEL-004)
Doepfer, Technical Details A-100 2026-10-16 Rails (BUS-001, BUS-006), pinout and marking (BUS-003, BUS-004), bus CV and gate jumper (BUS-016), bus CV and gate levels (BUS-017, BUS-018), gate thresholds (the GATE row of 7.2), 3.5 mm mono jacks (PANEL-005), the 10-pin header (BUS-007), split CV and gate regions and links (BUS-013, BUS-014), one CV and one gate transmitter per line (ASM-002). The patch audio and CV levels are EIS figures (Scope 1.4).
Doepfer, A-100 Accessories, A-100BUS V6 technical note 2026-10-14 Shrouded header keying (BUS-005) and module cable keying (BUS-010)
Doepfer, FAQ A-100, notes concerning bus boards with boxed pin headers 2026-10-14 Shrouded bus headers (BUS-005), with the row above
Intellijel, 1U technical specifications 2026-10-16 1U panel height 39.65 mm (PANEL-007)
Hinton Instruments, Power Distribution, last updated 2021-06-10 2026-10-24 The 5 mΩ limit of a supply cable (PWR-007); M4 ring terminals on the bars, which PWR-005 takes up as an EIS rule; one common 0 V for several supplies and the 2 mΩ ZeroVolt link (ASM-009, 6.3)